Based on the application of the limit-type hydraulic coupler on the double-toothed roller crusher, this paper analyzes the failure cause of the limit-type coupler due to impact load and puts forward the solution. The problem of the coupler in mineral sizers is effectively solved and the healthy operation level of the equipment is improved.
1 Limited moment fluid coupler in mineral sizers Application situation Limited moment fluid coupler hereinafter referred to as "coupling" is a kind of non-rigid coupling with liquid as the working medium, because it can make the motor start smoothly, reduce the impact and vibration during the motor start process, with overload protection. It has many advantages such as isolation of shock and torsional vibration and has been more and more widely used. The head of a 2 million tons building materials production line of our company is connected by a coupling between the motor YKK400 and the reducer, and the coupling type is TVA562. Shortly after the production line steel was put into operation, the coupling broke down frequently, which seriously affected the normal production. Because the production line uses the upper computer (computer and PLC centralized control mode, the computer can automatically record, store the motor current, voltage and other operating data, and display in the wave curve. Therefore, according to the clues such as the current fluctuation curve of the high-voltage motor, we carefully analyzed the reasons for the failure of the coupler, and finally completely solved the various problems existing in the coupler and related institutions to ensure the normal production.
There are five main problems in the application of couplings in mineral sizers. Shock vibration is the main cause of the problems, and the unreasonable design of the associated structure is also one of them: Coupler jitter generally after 2 months of use, the jitter gradually increases, resulting in frequent damage to the output bearing of the high voltage motor and the bearing of the input shaft of the reducer. The bearing of the high voltage motor is replaced once every 2 months on average, and the bearing of the input shaft of the reducer needs to be replaced once every 4 months on average. If the bearing is not replaced in time, once the bearing falls apart, the input shaft of the reducer will be broken. Reason analysis: The coupling is installed on the input shaft of the reducer, which is a helical gear shaft and is supported by an aligning roller bearing. The impact load of the crusher crushing large ore is transmitted to the input shaft of the reducer, and the input shaft moves axially, so that the bearing wear is accelerated and the radial clearance of the bearing is increased. In the case of the coupling cantilever installation structure and the dynamic balance is not good, the coupling must jitter. The axial force that the self-aligning roller bearing can withstand is limited, and the frequent bearing impact is also the cause of the excessive damage of the self-aligning roller bearing. Technical modification: The input shaft bearing is changed from an aligning roller bearing to a cone bearing, as shown in FIG. 1 and FIG. 1. The clearance of the cone bearing is adjusted by adjusting the thickness of the green shell paper at the end cover to keep the clearance within a reasonable range. The pinion can be prying until it feels easier to pry. Practice has proved that this method is very effective, reducing the runout of the coupler, and the flat key is rarely damaged. The service life of bearings has been increased from the original 4 months to more than 2 years.
Cause analysis: Although the bolt inside the coupling has an anti-loose spring sheet, the anti-loose spring sheet is easily broken in the case of severe shock and torsional vibration. Once there is a metal block inside the coupling, the coupling blade can be broken quickly when rotating at high speed. Disassembly and replacement is also a time-consuming and laborious thing. Technical transformation: the original internal bolts are bent and stuck nuts with steel sheets, and are now welded and locked with round steel, which is clumsy but effective. Coupling disassembly difficulty reason analysis: coupling shell is aluminum alloy material, disassembly and assembly can not use hammer method, coupling center and reducer input shaft are equipped with screw holes for disassembly, assembly screw holes are too small M24, matching press screw rod is also small, the pressure is not enough, assembly is difficult to disassemble screw holes M42×2, easy to mess up, disassembly is difficult. In the actual disassembly process, other disassembly and assembly tools must be attached, which is more complicated. Consult the manual and the design manual. The coupling is connected to the shaft assembly of the working machine for transition fit. The actual match, such as 110 + 2 wire, also meets the requirements, and the side deformation of the flat key is caused by impact torsional vibration, which is also one of the reasons for the difficulty of disassembly. Technical transformation: First, the screw hole at the end of the input shaft of the reducer is changed from M24 to M30, and the diameter of the press screw rod is increased: second, the screw hole at the center hole of the coupling is changed from M42×2 to T48×2: Third, the fit between the coupling and the input shaft of the reducer is still a transitional fit, and the interference is controlled within 0.02MM. 24 Coupling overheat injection in the production process, as long as there are more chunks in the supply source, the coupling will overheat injection, which not only consumes a lot of hydraulic transmission oil and wastes time, but also poses a serious threat to personal safety when the overheat transmission oil is emitted. According to the matching principle of the coupler: prime mover: working machine 1:1.05.1.1, the power of the three should be roughly 227:239:250. The rated power of the motor is 250KW, and the rated power of the coupling VA562 is 275KW, which meets the requirements of the matching principle. Why does the coupling frequently spray oil due to overheating, while the motor is not overloaded? Cause analysis: Since there was no spare coupling at the beginning, the elastic pin coupling ZL8 was used instead, the rated torque was 16000NM, and the maximum speed was 2500rpm. The maximum theoretical transmission power can reach 570KW. In less than 2 hours of actual use, the 12 40 nylon rods were soon all cut off, the upper computer (the computer shows that the overload peak current is about 110A, the average current is about 12A, and the impact load is very large. The coupler absorbs some of the impact kinetic energy and converts it into heat energy. However, when the frequency of crushing bulk ore exceeds a certain value, the heat dissipation of the coupler is not enough, and the internal oil temperature rises, resulting in fusible plug melting and oil spraying of the coupler. Technical transformation: Increase the rated transmission power of the matching coupler and choose a larger coupler. We changed the original coupler VA562 to YOX600. During the trial of the mineral sizers hydraulic coupler, the fuel volume starts from 80% of the rated fuel volume, and when it is found that the fuel volume reaches 95% of the rated value, the coupling tends to be stable. After more than 3 years of use, there is no oil injection phenomenon, and the motor works normally.
Coupling oil leakage vibration, high temperature, wear and other adverse factors cause coupling oil seal damage and oil leakage. Through the successful transformation of the first few items, the problem of coupling oil leakage has been solved.
3 Conclusion In the application of moment-limited hydraulic coupler with impact load, attention should be paid to the following points: When selecting the coupling, the upper limit of the theoretical calculation value should be taken or a larger coupling should be selected: 2 Attention should be paid to the anti-loose fasteners inside the coupling: 3 Due to the inevitable torsional vibration, attention should be paid to various factors that may cause the coupling to skip the bell, and try to avoid: 4 Try to keep the coupler well ventilated.