Henan Excellent Machinery Co., Ltd
+86-18337370596

Problems and preventive measures of deflagration of belt bucket elevator applied in fertilizer industry

Apr 26, 2022

Fertilizer Bucket Elevator is a kind of common vertical lifting equipment, which suitable for fertilizer industry. It has a simple structure, small footprint, low power consumption and large conveying capacity. Due to the characteristics of materials and various factors, Fertilizer Bucket Elevator machine adopts belt as a traction component, the transmission belt adopts fabric or wire rope core rubber belt, through the hopper fixed on the belt continuous upward conveying materials. Let us take you to understand the belt bucket elevator burst combustion problems and preventive measures:

Problems-and-preventive-measures-of-deflagration-of-belt-bucket-elevator

1.Belt bucket elevator explosion:

The actual explosion-proof device is to passively change the hoist in the early stages of deflagration closed state, so that the pressure inside the machine in time to release out. The size of the vent hole, part, number and its vent plate material for the explosion-proof effect of the larger impact. The head and seat is more likely to produce dust combustion parts, because these two places in the feed and discharge when the dust concentration is high and easy to start a fire, so the location of the vent hole should focus on the head and seat, the upper and lower barrels can be set up every few meters on a vent hole. The material of the explosion relief plate can be used waterproof cardboard, polyethylene plate, bin metal thin plate, mortar board, etc.

2.Explosion suppression of Belt bucket elevator:

Control dust deflagration automatic system has more future, the key to its advantage is that it can actively restrain the initial combustion of dust, the equipment in fact does not produce any significant pressure rise phenomenon, and will not be damaging, flammable and explosive generation, hot gas and flame exhaust into the air, the reason why the explosion suppression is possible, is due to deflagration from the beginning to a higher stage of development process. The basic principle of it is in the part prone to dust deflagration, the installation of a very sensitive pressure tester, when the machine pressure changes (that is, the initial stage of deflagration), through pressure sensing in a thousandth of a second to touch the fire extinguisher valve, the machine sprayed powder extinguishing agent.

3.The Belt bucket elevator fire source prevention.

One of the basic factors of dust deflagration - the source of fire, given that the value of the deflagration temperature often occurs in an instant, it is not easy to grasp the actual application, so manufacturing should be as far as possible to avoid the source of fire.